What is HAROLUX LED Stadium Light SS-SR04?
The HAROLUX SS-SR04 is a high-power LED stadium light designed for professional sports venues and large-area outdoor illumination. With selectable wattage from 300W to 1200W and luminous output up to 180,000 lumens, this fixture replaces traditional 1000W-4000W metal halide lamps while reducing energy consumption by up to 70%.
Engineered with an aluminum alloy housing and WET location rating, the SS-SR04 withstands harsh environments including parking garages, shipyard docks, airports, and industrial facilities. The optional laser designator enhances visibility for precision lighting applications.
Core Specifications at a Glance
| Parameter | Value |
|---|---|
| Power Range | 300W / 400W / 500W / 600W / 800W / 1000W / 1200W |
| Luminous Flux | 45,000 – 180,000 LM (Up to 150 LPW) |
| Color Temperature | 4000K / 5000K / 5700K Selectable |
| CRI | Ra >70 |
| Beam Angle | 15° / 25° / 40° / 60° / 80° Selectable |
| Input Voltage | AC120-277V / AC120-347V / AC277-480V |
| Operating Temp | -40°F ~ 113°F (-40°C ~ 45°C) |
| Protection Level | WET Location Rated |
| Material | Aluminum Alloy Housing |
| Lifespan | >50,000 Hours |
| Warranty | 5 Years Limited |
| Certifications | UL, ETL, DLC 5.1 Premium |
Product Images



Why Choose HAROLUX LED Stadium Light? (Top 5 Reasons)
1. Extreme Energy Savings
Compared to traditional metal halide stadium lights, the SS-SR04 delivers up to 150 lumens per watt—nearly double the efficiency of conventional 80-100 LPW HID fixtures. For a typical 1000W metal halide replacement, expect annual energy savings of $500-$800 per fixture.
2. Zero Maintenance for 5+ Years
With a 50,000-hour lifespan (11+ years at 12 hours/day), the SS-SR04 eliminates frequent lamp replacements. Traditional metal halide lamps require replacement every 8,000-15,000 hours—costing significant labor and downtime in hard-to-reach high-mast installations.
3. Instant On/Off & Flicker-Free
Unlike metal halide’s 10-20 minute warm-up time, LED stadium lights provide instant full brightness. This enables smart controls like motion sensors and scheduling. The flicker-free operation also ensures compatibility with HD broadcast cameras for televised events.
4. Precision Optics for Any Application
Selectable beam angles from 15° (tight spot) to 80° (wide flood) allow precise light distribution. The optional laser designator helps installers aim fixtures accurately, reducing spill light and light pollution while maximizing coverage where needed.
5. Built for Harsh Environments
The WET location rating and -40°F to 113°F operating range make the SS-SR04 ideal for coastal areas, parking garages, shipyards, and extreme climates where standard fixtures fail prematurely.
Detailed Model Specifications
| Model | Wattage | Lumen Output | Replaces | Beam Angle |
|---|---|---|---|---|
| SS-SR04-300W | 300W | 45,000 LM | 750W MH | 15°/25°/40°/60° |
| SS-SR04-400W | 400W | 60,000 LM | 1000W MH | 15°/25°/40°/60° |
| SS-SR04-500W | 500W | 75,000 LM | 1200W MH | 15°/25°/40°/60° |
| SS-SR04-600W | 600W | 90,000 LM | 1500W MH | 15°/40°/60°/80° |
| SS-SR04-800W | 800W | 120,000 LM | 2000W MH | 15°/40°/60°/80° |
| SS-SR04-1000W | 1000W | 150,000 LM | 2500W MH | 15°/25°/40°/60° |
| SS-SR04-1200W | 1200W | 180,000 LM | 3000W MH | 15°/40°/60°/80° |
| SS-SR04-Selectable | 600W/500W/400W/300W | 90,000 LM max | 750W-1500W MH | 15°/40°/60°/80° |
| SS-SR04-Selectable | 1000W/900W/800W/700W | 150,000 LM max | 1500W-2500W MH | 15°/40°/60°/80° |
LED vs Metal Halide: Side-by-Side Comparison
| Feature | Traditional Metal Halide | HAROLUX LED Stadium Light |
|---|---|---|
| Energy Efficiency | 80-100 LPW | Up to 150 LPW (50%+ savings) |
| Lifespan | 8,000-15,000 hours | >50,000 hours (5x longer) |
| Warm-up Time | 10-20 minutes | Instant on |
| Restrike Time | 15-20 minutes after power loss | Immediate |
| Maintenance | Frequent lamp & ballast replacement | Minimal maintenance |
| Light Quality | Color shift over time, UV emission | Consistent CCT, no UV |
| Dimming | Limited or none | 0-10V dimmable standard |
| Operating Cost (Annual) | $800-$1200 per fixture | $300-$500 per fixture |
Best Applications for HAROLUX LED Stadium Light
Sports Venues (Primary Use)
- Football stadiums: 30-50 foot-candles for amateur, 75+ for professional
- Soccer fields: Uniform illumination across 100m x 64m pitch
- Baseball diamonds: Infield 50 fc, outfield 30 fc minimum
- Tennis/basketball courts: Glare-free lighting for player visibility
- Running tracks: Consistent horizontal and vertical illuminance
Transportation & Infrastructure
- Airport aprons & runways: High reliability for safety-critical operations
- Shipyard docks: Corrosion-resistant for marine environments
- Parking garages: 24/7 operation with occupancy sensor compatibility
- Toll plazas: Clear visibility for license plate recognition
Industrial & Commercial
- Factory yards: Loading dock illumination and security perimeter
- Construction sites: Temporary high-mast lighting
- Large warehouses: Exterior loading areas and truck courts
- Distribution centers: 24-hour operational lighting
Installation Guidelines
Mounting Height Recommendations
| Application | Recommended Height | Spacing |
|---|---|---|
| Small sports courts (tennis/basketball) | 20-30 feet | 40-60 feet |
| Baseball/softball fields | 40-60 feet | 80-120 feet |
| Football/soccer stadiums | 50-100 feet | 100-200 feet |
| Parking lots | 20-40 feet | 4-6 times mounting height |
| Industrial yards | 30-60 feet | Based on area coverage needs |
Aiming & Optics Selection
- 15° beam: Long-throw applications (perimeter lighting, distant targets)
- 25° beam: Medium-throw sports lighting (outfield, track)
- 40° beam: General area lighting (parking, general sports)
- 60°-80° beam: Wide coverage (infield, courts, low mounting)
Customization & Accessories
- Photocell sensor: Automatic dusk-to-dawn operation ($25 add-on)
- Motion sensor: Occupancy-based dimming for parking applications
- Wireless controls: Remote monitoring, scheduling, and group control
- Surge protection: 10kV surge suppressor for lightning-prone areas
- Special voltages: 347V (Canada), 480V (industrial) available
- Custom CCT: 2700K-6500K available for special projects
- Private labeling: OEM branding with MOQ 100 units
Frequently Asked Questions (FAQ)
What is the best LED stadium light for a high school football field?
For a standard high school football field (360′ x 160′), we recommend 24-32 x SS-SR04-600W fixtures mounted at 60-80 feet, providing 30-50 foot-candles for competitive play. The selectable wattage models allow adjustment based on specific league requirements.
How many lumens do I need for a soccer stadium?
Professional soccer requires 75-200 foot-candles depending on broadcast level. For a FIFA-compliant stadium, plan on 200,000-400,000 total lumens per field. Amateur/community fields typically need 30-50 foot-candles (approximately 100,000-150,000 lumens).
Can LED stadium lights be used for broadcast television?
Yes. The HAROLUX SS-SR04 features flicker-free operation and Ra>70 CRI, making it suitable for HD broadcast. For professional TV production, specify 5700K color temperature and ensure uniformity ratios meet broadcast standards (U1 >0.7, U2 >0.5).
What is the payback period for LED stadium lights?
Most customers see a 2-4 year payback through combined energy savings (50-70%), reduced maintenance costs (eliminating lamp changes), and utility rebates. DLC Premium certification makes the SS-SR04 eligible for maximum rebate programs.
Do you offer installation support?
Yes. HAROLUX provides photometric layouts, aiming diagrams, and installation guidance. For large projects, we can recommend certified contractors familiar with high-mast sports lighting installation.
What warranty comes with HAROLUX LED stadium lights?
The SS-SR04 includes a 5-year limited warranty covering driver and LED module failure. Extended warranties up to 10 years are available for qualified projects.
Get a Custom Quote
Ready to upgrade your sports facility or outdoor lighting? Contact HAROLUX for:
- Free photometric layout and lighting design
- Project-specific pricing and volume discounts
- Sample evaluation program
- OEM/private label opportunities
Last updated: March 2026 | Technical specifications subject to change. Consult factory for latest information.