HAROLUX LED Stadium Light SS-SR04 Main

What is HAROLUX LED Stadium Light SS-SR04?

The HAROLUX SS-SR04 is a high-power LED stadium light designed for professional sports venues and large-area outdoor illumination. With selectable wattage from 300W to 1200W and luminous output up to 180,000 lumens, this fixture replaces traditional 1000W-4000W metal halide lamps while reducing energy consumption by up to 70%.

Engineered with an aluminum alloy housing and WET location rating, the SS-SR04 withstands harsh environments including parking garages, shipyard docks, airports, and industrial facilities. The optional laser designator enhances visibility for precision lighting applications.

Core Specifications at a Glance

Parameter Value
Power Range 300W / 400W / 500W / 600W / 800W / 1000W / 1200W
Luminous Flux 45,000 – 180,000 LM (Up to 150 LPW)
Color Temperature 4000K / 5000K / 5700K Selectable
CRI Ra >70
Beam Angle 15° / 25° / 40° / 60° / 80° Selectable
Input Voltage AC120-277V / AC120-347V / AC277-480V
Operating Temp -40°F ~ 113°F (-40°C ~ 45°C)
Protection Level WET Location Rated
Material Aluminum Alloy Housing
Lifespan >50,000 Hours
Warranty 5 Years Limited
Certifications UL, ETL, DLC 5.1 Premium

Product Images

LED Stadium Light Side View

LED Stadium Light Detail

LED Stadium Light Application

Why Choose HAROLUX LED Stadium Light? (Top 5 Reasons)

1. Extreme Energy Savings

Compared to traditional metal halide stadium lights, the SS-SR04 delivers up to 150 lumens per watt—nearly double the efficiency of conventional 80-100 LPW HID fixtures. For a typical 1000W metal halide replacement, expect annual energy savings of $500-$800 per fixture.

2. Zero Maintenance for 5+ Years

With a 50,000-hour lifespan (11+ years at 12 hours/day), the SS-SR04 eliminates frequent lamp replacements. Traditional metal halide lamps require replacement every 8,000-15,000 hours—costing significant labor and downtime in hard-to-reach high-mast installations.

3. Instant On/Off & Flicker-Free

Unlike metal halide’s 10-20 minute warm-up time, LED stadium lights provide instant full brightness. This enables smart controls like motion sensors and scheduling. The flicker-free operation also ensures compatibility with HD broadcast cameras for televised events.

4. Precision Optics for Any Application

Selectable beam angles from 15° (tight spot) to 80° (wide flood) allow precise light distribution. The optional laser designator helps installers aim fixtures accurately, reducing spill light and light pollution while maximizing coverage where needed.

5. Built for Harsh Environments

The WET location rating and -40°F to 113°F operating range make the SS-SR04 ideal for coastal areas, parking garages, shipyards, and extreme climates where standard fixtures fail prematurely.

Detailed Model Specifications

Model Wattage Lumen Output Replaces Beam Angle
SS-SR04-300W 300W 45,000 LM 750W MH 15°/25°/40°/60°
SS-SR04-400W 400W 60,000 LM 1000W MH 15°/25°/40°/60°
SS-SR04-500W 500W 75,000 LM 1200W MH 15°/25°/40°/60°
SS-SR04-600W 600W 90,000 LM 1500W MH 15°/40°/60°/80°
SS-SR04-800W 800W 120,000 LM 2000W MH 15°/40°/60°/80°
SS-SR04-1000W 1000W 150,000 LM 2500W MH 15°/25°/40°/60°
SS-SR04-1200W 1200W 180,000 LM 3000W MH 15°/40°/60°/80°
SS-SR04-Selectable 600W/500W/400W/300W 90,000 LM max 750W-1500W MH 15°/40°/60°/80°
SS-SR04-Selectable 1000W/900W/800W/700W 150,000 LM max 1500W-2500W MH 15°/40°/60°/80°

LED vs Metal Halide: Side-by-Side Comparison

Feature Traditional Metal Halide HAROLUX LED Stadium Light
Energy Efficiency 80-100 LPW Up to 150 LPW (50%+ savings)
Lifespan 8,000-15,000 hours >50,000 hours (5x longer)
Warm-up Time 10-20 minutes Instant on
Restrike Time 15-20 minutes after power loss Immediate
Maintenance Frequent lamp & ballast replacement Minimal maintenance
Light Quality Color shift over time, UV emission Consistent CCT, no UV
Dimming Limited or none 0-10V dimmable standard
Operating Cost (Annual) $800-$1200 per fixture $300-$500 per fixture

Best Applications for HAROLUX LED Stadium Light

Sports Venues (Primary Use)

  • Football stadiums: 30-50 foot-candles for amateur, 75+ for professional
  • Soccer fields: Uniform illumination across 100m x 64m pitch
  • Baseball diamonds: Infield 50 fc, outfield 30 fc minimum
  • Tennis/basketball courts: Glare-free lighting for player visibility
  • Running tracks: Consistent horizontal and vertical illuminance

Transportation & Infrastructure

  • Airport aprons & runways: High reliability for safety-critical operations
  • Shipyard docks: Corrosion-resistant for marine environments
  • Parking garages: 24/7 operation with occupancy sensor compatibility
  • Toll plazas: Clear visibility for license plate recognition

Industrial & Commercial

  • Factory yards: Loading dock illumination and security perimeter
  • Construction sites: Temporary high-mast lighting
  • Large warehouses: Exterior loading areas and truck courts
  • Distribution centers: 24-hour operational lighting

Installation Guidelines

Mounting Height Recommendations

Application Recommended Height Spacing
Small sports courts (tennis/basketball) 20-30 feet 40-60 feet
Baseball/softball fields 40-60 feet 80-120 feet
Football/soccer stadiums 50-100 feet 100-200 feet
Parking lots 20-40 feet 4-6 times mounting height
Industrial yards 30-60 feet Based on area coverage needs

Aiming & Optics Selection

  • 15° beam: Long-throw applications (perimeter lighting, distant targets)
  • 25° beam: Medium-throw sports lighting (outfield, track)
  • 40° beam: General area lighting (parking, general sports)
  • 60°-80° beam: Wide coverage (infield, courts, low mounting)

Customization & Accessories

  • Photocell sensor: Automatic dusk-to-dawn operation ($25 add-on)
  • Motion sensor: Occupancy-based dimming for parking applications
  • Wireless controls: Remote monitoring, scheduling, and group control
  • Surge protection: 10kV surge suppressor for lightning-prone areas
  • Special voltages: 347V (Canada), 480V (industrial) available
  • Custom CCT: 2700K-6500K available for special projects
  • Private labeling: OEM branding with MOQ 100 units

Frequently Asked Questions (FAQ)

What is the best LED stadium light for a high school football field?

For a standard high school football field (360′ x 160′), we recommend 24-32 x SS-SR04-600W fixtures mounted at 60-80 feet, providing 30-50 foot-candles for competitive play. The selectable wattage models allow adjustment based on specific league requirements.

How many lumens do I need for a soccer stadium?

Professional soccer requires 75-200 foot-candles depending on broadcast level. For a FIFA-compliant stadium, plan on 200,000-400,000 total lumens per field. Amateur/community fields typically need 30-50 foot-candles (approximately 100,000-150,000 lumens).

Can LED stadium lights be used for broadcast television?

Yes. The HAROLUX SS-SR04 features flicker-free operation and Ra>70 CRI, making it suitable for HD broadcast. For professional TV production, specify 5700K color temperature and ensure uniformity ratios meet broadcast standards (U1 >0.7, U2 >0.5).

What is the payback period for LED stadium lights?

Most customers see a 2-4 year payback through combined energy savings (50-70%), reduced maintenance costs (eliminating lamp changes), and utility rebates. DLC Premium certification makes the SS-SR04 eligible for maximum rebate programs.

Do you offer installation support?

Yes. HAROLUX provides photometric layouts, aiming diagrams, and installation guidance. For large projects, we can recommend certified contractors familiar with high-mast sports lighting installation.

What warranty comes with HAROLUX LED stadium lights?

The SS-SR04 includes a 5-year limited warranty covering driver and LED module failure. Extended warranties up to 10 years are available for qualified projects.

Get a Custom Quote

Ready to upgrade your sports facility or outdoor lighting? Contact HAROLUX for:

  • Free photometric layout and lighting design
  • Project-specific pricing and volume discounts
  • Sample evaluation program
  • OEM/private label opportunities

    Last updated: March 2026 | Technical specifications subject to change. Consult factory for latest information.